The Importance of Bathroom Fans and Ducts

- Most are controlled by a conventional wall switch.
- A timer switch may be mounted on the wall.
- A wall-mounted humidistat can be pre-set to turn the fan on and off based on different levels of relative humidity
.
Bathroom ventilation fans should be inspected for dust buildup that can impede air flow. Particles of moisture-laden animal dander and lint are attracted to the fan because of its static charge. Inspectors should comment on dirty fan covers.
- moisture stains on walls or ceilings;
- corrosion of metal;
- visible mold on walls or ceilings;
- peeling paint or wallpaper;
- frost on windows; and
- high levels of humidity.
- mid-level in the attic. These are easy to spot;
- beneath the insulation. You need to remember to look. The duct may terminate beneath the insulation or there may be no duct installed; and
- under attic vents. The duct must terminate at the home exterior, not just under it.
Mold is impossible to identify visually and must be tested by a lab in order to be confidently labeled. Inspectors should refrain from calling anything “mold” but should refer to anything that appears as mold as a material that “appears to be microbial growth.” Inspectors should include in their report, and in the inspection agreement signed by the client, a disclaimer clearly stating that the General Home Inspection is an inspection for safety and system defects, not a mold inspection.
Decay, which is rot, is also caused by fungi. Incipient or early decay cannot be seen. By the time decay becomes visible, affected wood may have lost up to 50% of its strength.
In order to grow, mold fungi require the following conditions to be present:
- oxygen;
- temperatures between approximately 45° F and 85° F;
- food. This includes a wider variety of materials found in homes; and
- moisture.
Even though mold growth may take place in the attic, mold spores can be sucked into the living areas of a residence by low air pressure. Low air pressure is usually created by the expulsion of household air from exhaust fans in bathrooms, dryers, kitchens and heating equipment.
- terminate outdoors. Ducts should never terminate within the building envelope;
- contain a screen or louvered (angled) slats at its termination to prevent bird, rodent and insect entry;
- be as short and straight as possible and avoid turns. Longer ducts allow more time for vapor to condense and also force the exhaust fan to work harder;
- be insulated, especially in cooler climates. Cold ducts encourage condensation;
- protrude at least several inches from the roof;
- be equipped with a roof termination cap that protects the duct from the elements; and
- be installed according to the manufacturer's recommendations.
- be made from inflexible metal, PVC, or other rigid material. Unlike dryer exhaust vents, they should not droop; and
- have smooth interiors. Ridges will encourage vapor to condense, allowing water to back-flow into the exhaust fan or leak through joints onto vulnerable surfaces.
International Association of Certified Home Inspectors (InterNACHI) is the world's most elite, non-profit inspection association.
President, ComInspect, www.cominspect.com
Director, Master Inspector Certification Board, www.certifiedmasterinspector.org
Author, 15 books and Co-Host of http://www.NACHI.TV
And a note From Judy: If you have a question about buying or selling a home in Fairfield County, and are in need of an Realtor to represent you, I invite you to contact me, and if you have an idea for a topic that you would like to see on The CT Realty Blog, please include it in the "Post a Comment" section link below this post. We appreciate the feedback and look forward to providing you with the best real estate content, advice and service in Fairfield County, Connecticut.
Reader Comments